Copyright © Jiangxi Ruihua Intelligent Technology Co., Ltd. All Rights Reserved. Site Map
EU Standard DC EV Charger | |||
Parameter | Name | RHDC60K-YJG-EU | RHDC120K-YJG-EU |
Input | Power Supply | 3P+N+PE | 3P+N+PE |
Input Voltage | 380V/AC±15% | 380V/AC±15% | |
Input Frequency | 50/60 Hz | 50/60 Hz | |
Input PF | ≥0.98 | ||
Total Harmonics of Input Current | ≤5% ( 50%~100% loading ) | ||
Output | Output Rated Power | 60kW | 120kW |
Output Rated Voltage | 1000V/DC | ||
Output Rated Current | 60A | 120A | |
Voltage Range | 150-1000V/DC | ||
Constant Power Output Voltage Range | 300-1000V/DC | ||
Maximum Current of Each Gun | 200A | ||
Current Range of Each Gun | 5-200A | ||
Maximum Efficiency | ≥95% ( FullLoading ) | ||
Steady Current Accuracy | ≤±1% | ||
Steady Voltage Accuracy | ≤±0.5% | ||
User Interface | LED Indicator | LED( Green、Yellow、Red ) | |
LCD Display | 7”Color Touch Screen | ||
Start Mode | Plug&Play,RFID Card,APP | ||
Cable Length | 5m | ||
Number of Gun | Double | ||
Communication | LAN | Yes | |
4G | Yes | ||
OCPP | OCPP1.6J | ||
Protection | Short Circuit Protection | Yes | |
Over Load Protection | Yes | ||
Over Temperature Protection | Yes | ||
Leakage Protection | Yes | ||
Over and Under Input Voltage Protection | Yes | ||
Over and Under Output Voltage Protection | Yes | ||
Output Over Current | Yes | ||
Standaro | IEC 61851-1:2017,IEC 61851-23:2014,EN 61851-24:2014,EN 61851-21-1:2018 | ||
Environmental | Work Temperature | -20℃~+55℃ | |
Storage Temperature | -40℃~+85℃ | ||
Work Humidity | ≤95%Dew Free | ||
Work Altitude | ≤2000m | ||
Work Condition | Indoor or Outdoor | ||
Others | Cooling Mode | Air Cooling(Independent Air Duct) | |
Noise | ≤65dB | ||
Ingress Protection | IP65 | ||
Electric Energy Measurement | 1.0 level | ||
Installation | Floor-stand | ||
Product Dimension | 1780*800*950mm(H*W*D) | ||
Net Weight | 390kc | 420kg | |
Package | Wood Case |